The Alpha boiler fault codes people most often see are E28 for ignition failure, E10 for low water pressure (simple top up DIY), E9 for a fan fault and E37 for a low voltage or circuit board problem. These lock the boiler out, so you lose heating and hot water until the cause is found.
Alpha makes the E-Tec, InTec and Evoke ranges, and the code list isn’t identical across all of them. That’s worth knowing before you go searching, because a code on the very popular Alpha E-Tec doesn’t always mean the same as one on an older InTec.
We repair, service and replace boilers across every Edinburgh postcode from EH1 to EH55 and towns including Balerno, Bonnyrigg, Dalkeith, Linlithgow, Musselburgh, Penicuik and South Queensferry, and Alpha boilers come through our hands regularly. If yours is more than around eight years old and out of warranty, repeat faults are a good reason to price up a replacement.
Which Alpha Boiler do you have, and where do you find the right codes?
Check the model name on the front panel or data plate, because the code list depends on the range. The E-Tec, E-Tec Plus, InTec and Evoke models use E codes on a digital display, and some older ranges use numbered codes.
Once you know your model, the user manual and the installation and servicing manual list every code for it. The servicing manual is the one engineers work from. If you can’t find yours, an engineer can read the code and tell you what it means on your exact boiler.
Common Alpha boiler fault codes list
| Code | What it usually means | Can you do anything yourself? |
|---|---|---|
| E28 | Ignition failure, no flame established | Check gas supply, reset once |
| E10 | Low water pressure (code varies by model) | Top up through the filling loop |
| E9 | Fan fault | Check the flue terminal, reset once |
| E37 | Low voltage or circuit board fault | Reset once, then call an engineer |
These cover the faults we see most. Your manual lists the full set for your model.
E28: ignition failure
E28 means the boiler tried to light and couldn’t establish a flame, so it locked out. It’s the most common reason people call an engineer about an Alpha.
Start with the basics. Do your hob or other gas appliances work? On LPG, is there gas in the tank?
On winter mornings, a frozen condensate pipe can also stop a condensing boiler from firing, so check the outside run and defrost your frozen condensate pipe with warm water, never boiling. Reset once. If E28 returns, the ignition electrode, flame sensing or gas valve needs testing, and that has to be done by a Gas Safe engineer.
One thing we do see: a boiler that shows E28 on cold mornings but works fine later is worth telling your engineer about, as it points to a particular set of causes.
E10: low water pressure
E10 means the system pressure has dropped below the safe minimum, and It’s the code you can most often clear yourself.
The gauge should read about 1 to 1.5 bar when the system is cold. On many Alpha models the filling loop is a braided hose with two small valves inside the casing at the base.
- Open them slowly until the needle reaches about 1.2 bar, close them firmly and press reset.
- Check the pressure again over the next few days.
If it keeps falling, there’s a leak or an expansion vessel problem, and an engineer should look at it.
E9 error: fan fault
E9 means the boiler isn’t getting the fan speed it expects. Alpha boilers monitor the fan closely, so a dirty fan or a worn bearing can trigger it before the fan fails completely.
Look at the flue terminal outside for anything blocking it, keep the area around the boiler clear, and reset once. If the E9 error returns, the fan, its wiring or the circuit board needs checking by a Gas Safe engineer.
E37 error: low voltage or circuit board fault
E37 points to a low voltage reading, and on some InTec models it has been traced to a fault on the main circuit board. It can come and go, appearing when a tap is turned on and clearing when it’s turned off.
If E37 appears occasionally, it’s worth mentioning to your engineer even if it clears itself. A repeated E37 usually means a board repair or replacement, and on an older boiler that’s a cost to weigh against a new one.
Older Alpha models with numbered codes
Some older ranges show numbered codes, such as 4 for a gas valve connection fault or 16 for a fan fault, rather than E codes.
The meanings are specific to the range, so use the manual for your model or ask an engineer to read it. These boilers are often well past the age where we’d recommend major repairs.
Need help with an Alpha boiler in Edinburgh or Scotland?
The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland.
Our Gas Safe engineers are Which? Trusted Traders, and our installation team can talk you through your options if your Alpha has reached the end of its useful life. Book an Alpha repair with our team or request a free quote for a new boiler. Got a different make? Our guide to boiler error codes for every major brand covers the rest.
Frequently asked questions about Alpha fault codes
Do all Alpha boilers use the same fault codes?
No. The code list varies between the E-Tec, InTec and Evoke ranges, and older models use numbered codes. Check the manual for your model.
How often should an Alpha boiler be serviced?
Once a year by a Gas Safe engineer. A boiler service checks electrodes, the fan, sensors and the condensate path before they cause a lockout.
Is it worth repairing an older Alpha?
If it’s over eight years old, out of warranty and showing repeat faults, a replacement often works out better value over a few years. We’ll give you both figures side by side.
What should I do if I smell gas?
Turn the boiler off at the isolator, open windows, avoid electrical switches and call the National Gas Emergency number on 0800 111 999.
How many times can I reset my Alpha?
Once. If the code returns, repeated resets won’t fix the cause, and a Gas Safe engineer needs to take a look.