Quick answer: DEAIR on a Baxi boiler isn’t a fault. It’s an automatic venting cycle that clears air from the boiler and heating system every time the power comes back on. On the Baxi Assure 500 it lasts 6 minutes 20 seconds, then the boiler starts working normally. Leave it alone and let it finish.
I get a lot of calls about this one, usually from someone who’s just had a power cut or a brand-new boiler fitted and is staring at a screen saying DEAIR. If that’s you, please don’t worry. Nothing has broken. The boiler is doing a sensible little routine before it lights. Baxi’s 800 and Assure ranges are very popular in Edinburgh flats and new-builds, so it’s a message plenty of our customers will see sooner or later.
What does deAir mean on a Baxi boiler?
DeAir is short for de-aeration. The boiler runs its pump in a set pattern to push trapped air out of the heat exchanger and pipework before it fires up.
Air in a heating system causes noise, poor circulation and, in the worst cases, overheating. Clearing it first protects the boiler. According to the Baxi Assure 500 installation manual, the screen alternates between a dashed line, the word DEAIR and the heating pressure while the cycle runs.
How long does deAir last?
On the Assure 500 it’s 6 minutes 20 seconds. Other current Baxi models run a similar cycle of around six to seven minutes.
The exact time can vary between models and software versions, so if yours seems to take a little longer, that’s usually nothing to worry about. Your user manual will give the figure for your boiler. Long enough to put the kettle on, anyway.
Why has deAir appeared on my boiler?
DeAir runs whenever the boiler gets its power back. The usual reasons are:
| What happened | Is it normal? | What to do |
|---|---|---|
| Power cut in the street or a tripped switch | Yes | Wait for it to finish |
| Boiler switched off and on at the spur | Yes | Wait for it to finish |
| New boiler just installed | Yes | Wait, it may run more than once in the first day |
| After an engineer’s visit or repair | Yes | Wait for it to finish |
| Appears again and again with no power loss | Not usually | Check the pressure, then call an engineer |
If you saw DEAIR after the lights flickered during a winter storm, that’s exactly why. Scotland gets its share of those.
What if deAir keeps coming back or the pressure is low?
Check the pressure first. With the heating cold, it should sit around 1 to 1.5 bar. If it’s low, top it up using the filling loop as your user guide describes.
A deAir cycle can shift a little air out of the radiators, so a small pressure drop afterwards is normal on a new or recently drained system. What isn’t normal is a pressure drop that keeps happening. That points to a leak or a faulty part, and topping up week after week only hides the problem. If the boiler then shows E119 or H.02.07, those are the low-pressure codes, and our guides explain what to do next.
Can I skip or turn off deAir?
It’s an engineer-level setting, and I’d always advise leaving it on. The cycle only costs you a few minutes, and it protects the boiler from running with air trapped inside.
If a cycle has run and the boiler still won’t light, don’t keep switching it off and on to force another one. That just restarts the clock. Give us a call instead.
When should I call an engineer?
Call a Gas Safe engineer if deAir is followed by a fault code, if the pressure keeps dropping, or if the boiler gurgles and bangs once it’s running.
Gurgling after deAir usually means there’s still air in the system, or circulation isn’t right. It’s a quick job for an engineer to bleed the system properly and check the pump. If a Baxi E1 code appears, note down the full number that follows, as it tells us a lot before we arrive.
Baxi boiler repairs across Edinburgh and Scotland
The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland. Our Gas Safe engineers cover every Edinburgh postcode from EH1 to EH55, as well as Livingston, Dalkeith, Musselburgh, Penicuik and Bathgate. We’re Which? Trusted Traders, and Baxi boilers are a daily part of our work. If your Baxi isn’t behaving after its deAir cycle, arrange a Baxi repair and we’ll sort it. And if your boiler is over eight years old and out of warranty and starting to cause bother, a new boiler from our Edinburgh team may save you money in the long run. Our Baxi error code guide covers the codes that do mean a fault.
Frequently asked questions about the Baxi deAir code
Is deAir a fault?
No. It’s a normal start-up routine. The boiler will go back to normal on its own once the cycle finishes.
Why does my Baxi say deAir after a power cut?
Because the boiler restarts its full start-up sequence whenever the power returns, and deAir is part of that sequence.
Can I use hot water while deAir is running?
Not until it finishes. The boiler won’t fire during the cycle, so the hot water will run cold for a few minutes.
Does deAir mean there’s air in my radiators?
Not necessarily. The cycle runs every time as a precaution. If your radiators are cold at the top once the heating is on, though, they may need bleeding.