Trustpilot and STV

Baxi E168 Error Code: Causes and How to Fix It

Quick answer: The Baxi E168 code means the boiler has detected a problem but can’t work out exactly what it is. It often appears after a reset, a power cut or another fault. Make a note of any code you saw before it, switch the boiler off at the isolator for a minute, then try one reset. If E168 returns, you need a Gas Safe engineer.

Baxi boilers are very popular across Edinburgh and the Lothians, and E168 is one of the more puzzling codes because it doesn’t point at a single part. Please don’t be put off by that. It’s usually something an engineer can track down quickly, and plenty of the time it clears after a simple restart. If your Baxi is more than around eight years old and out of warranty, repeat faults like this are a fair reason to look at a new boiler from our Edinburgh team.

What does the Baxi E168 error code mean?

E168 means the boiler has found a fault but can’t say exactly what it is. Think of it as the boiler’s way of saying something’s wrong without knowing where.

Baxi’s own guidance explains that it can appear because the boiler was reset after developing a fault, or because of an external issue such as a problem with the electrical supply. That’s why it sometimes turns up out of the blue and then disappears.

What causes a Baxi E168 fault?

The usual causes are an earlier fault that was reset, a problem with the electrical supply, or a fault with the circuit board or its connections.

  • A reset after another fault: the original code has gone, but the underlying problem hasn’t
  • Electrical supply issues: power cuts, surges or a poor supply can confuse the control board
  • Circuit board or wiring: an intermittent fault in the board or its connections

It’s also worth knowing that Potterton and Main boilers use the same E168 code.

How do you fix a Baxi E168 error?

Note any other code that appeared before it, switch the boiler off at the isolator for a minute, switch it back on and try one reset.

  1. Think back: did the boiler show a different code before E168 appeared? If so, write it down for your engineer.
  2. Switch the boiler off at the isolator or fused spur for about a minute.
  3. Switch it back on and press reset once.
  4. If the boiler works normally, keep an eye on it over the next few days.
  5. If E168 returns, leave it and book a Gas Safe engineer.

The circuit board and wiring are not for home repair, so please don’t take the casing off. We’re happy to take a look.

Why does E168 keep coming back?

A repeating E168 usually means something is still wrong underneath, such as an intermittent circuit board or wiring fault. Resetting clears the symptom for a while, but it doesn’t fix the cause.

If it comes and goes, which can be frustrating, tell your engineer when it happens, such as after a power cut, at certain times of day or when a particular tap is on. Those details speed up the diagnosis.

Does servicing help prevent E168?

It helps, because a yearly boiler service lets an engineer check connections, sensors and the supply to the boiler before small issues grow. It’s also a good moment to ask about any odd behaviour you’ve noticed.

When should you call an engineer for a Baxi E168?

Call a Gas Safe engineer if E168 returns after one reset, appears repeatedly, or comes with other codes or odd behaviour. Baxi itself advises contacting your installer if it persists. If the boiler is still in its warranty period, check the terms and your service record first.

Baxi boiler repairs across Edinburgh and Scotland

The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland. Our Gas Safe engineers cover every Edinburgh postcode from EH1 to EH55 and towns including Balerno, Bonnyrigg, Dalkeith, Linlithgow, Musselburgh, Penicuik and South Queensferry. We’re Which? Trusted Traders, and Baxi faults are part of our weekly routine. If your boiler is showing E168, book a Baxi repair with our team and we’ll get to the bottom of it.

Frequently asked questions about the Baxi E168 error

Is a Baxi E168 fault dangerous?

Try not to worry, the lockout is protective, so it’s the safe outcome. If you ever smell gas, turn the boiler off at the isolator, open windows and call the National Gas Emergency number on 0800 111 999.

How many times should I reset my Baxi after E168?

Once, so don’t worry if you’ve already tried it. If the code returns, repeated resets won’t solve the underlying problem.

Can a power cut cause E168?

Yes, an electrical supply problem is one of the reasons Baxi gives for the code. If it appeared after a power cut and clears with a restart, keep an eye on it. If it keeps returning, it needs an engineer.

What other Baxi codes should I know about?

The Baxi E119 is low pressure, and the Baxi E133 is an ignition or gas supply fault. Our guide to Baxi boiler error codes lists the rest.

Is it worth repairing an older Baxi that keeps showing E168?

If it’s over eight years old and out of warranty, intermittent electrical faults are often a sign more are coming. A Gas Safe engineer can give you a clear repair-or-replace comparison, and you can request a free quote at the same visit.