Quick answer: The Glow-worm F1 fault code means an ignition fault. The boiler tried to light the burner and couldn’t establish a flame, so it locked out. Common causes are a gas supply problem, a worn ignition electrode or a faulty gas valve. Check your other gas appliances, reset once, and if F1 returns, call a Gas Safe engineer.
Glow-worm is a very popular name in Scottish homes, and an F1 on the display is one of the more common reasons we get called out. If your heating and hot water have stopped, please try not to worry. It’s a well-known fault, and the first checks are quick. If your Glow-worm is more than around eight years old and out of warranty, repeat ignition faults are a fair reason to look at a new boiler from our Edinburgh team.
What does the Glow-worm F1 fault code mean?
F1 means an ignition fault. The boiler tried to light the burner and didn’t get a flame.
Glow-worm’s own fault code tables list F1 as an ignition fault on ranges such as the Flexicom and the CI range. The boiler normally makes several attempts to light, and if none succeeds it locks out for safety.
The exact numbering varies by range. On some Glow-worm models, ignition failure is shown as F28 instead, so check which range yours is.
What causes a Glow-worm F1 fault?
The usual causes are a gas supply problem, a worn or dirty ignition electrode, a faulty gas valve or an ignition control problem.
- Gas supply: the gas is off, the supply is interrupted, or an LPG tank is running low
- Ignition electrode: worn or dirty, so the spark or flame sensing is weak
- Gas valve: not delivering gas properly
- Control board: less common, and the last thing we’d suspect
How do you fix a Glow-worm F1 fault?
Check that other gas appliances work, press reset once, and if F1 returns, switch the boiler off and call a Gas Safe engineer.
- Try your hob or another gas appliance. If they don’t work either, the issue is the gas supply, not the boiler.
- If you’re on LPG, check the tank level.
- Press reset once and give the boiler a minute to try again.
- If F1 comes back, leave the boiler off and book a Gas Safe engineer.
The electrode, gas valve and control board are engineer jobs, so please don’t open the casing. If you ever smell gas, switch the boiler off, open windows, avoid light switches and call 0800 111 999.
Does a boiler service prevent F1 faults?
It certainly helps, because a yearly boiler service lets an engineer check the electrode, burner and gas valve before they cause a lockout. A worn electrode found in a service is a cheap swap, whereas one found on a cold January morning is not.
When should you call an engineer for a Glow-worm F1?
Call a Gas Safe engineer if F1 returns after one reset, if other gas appliances work fine, or if the boiler lights and then cuts out. Ignition work involves gas components, so it has to be done by someone qualified. If the boiler is still under warranty, check the terms and contact Glow-worm first if needed.
Glow-worm boiler repairs across Edinburgh and Scotland
The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland. Our Gas Safe engineers cover every Edinburgh postcode from EH1 to EH55, plus Balerno, Bonnyrigg, Dalkeith, Linlithgow, Musselburgh, Penicuik and South Queensferry. We’re Which? Trusted Traders, and ignition faults are a regular part of our winter. If your Glow-worm is showing F1, book a Glow-worm engineer visit and we’ll get your heating back on.
Frequently asked questions about the Glow-worm F1 fault
Is a Glow-worm F1 fault dangerous?
The lockout is the boiler protecting you, so it’s the safe outcome. If you ever smell gas, turn the boiler off at the isolator, open windows and call the National Gas Emergency number on 0800 111 999.
How many times should I reset my Glow-worm after F1?
Once. If the code returns, repeated resets won’t fix a worn electrode or a gas supply problem, and each attempt just repeats the failed ignition.
What’s the difference between Glow-worm F1 and F28?
Both relate to ignition. Which one your boiler shows depends on the range, and our guide to the Glow-worm F28 covers the other version. Our guide to Glow-worm boiler error codes lines them up.
Is it worth repairing an older Glow-worm that keeps showing F1?