Quick answer: Glow-worm F29 means the burner lit, then the flame went out while the boiler was running. The usual causes are a gas supply hiccup, a frozen condensate pipe in cold weather, or a fault with the ignition spark. Check your other gas appliances and your meter credit, then reset the boiler once.
Glow-worm is a very popular make in Scottish homes, so we see this code fairly often, especially when the temperature drops. I know it’s miserable when the heating cuts out, but most F29 faults turn out to be fixable.
What does F29 mean on a Glow-worm boiler?
F29 is Glow-worm’s code for loss of flame during operation. The boiler started up and lit as it should, then the flame disappeared part way through the heating or hot water demand.
It shows on the newer Glow-worm models, including the Energy range, the Ultracom2 and the Betacom. It isn’t listed on the older Flexicom or CI boilers, which use different codes. If yours is an older boiler, check the manual or the Glow-worm error code guide before assuming F29 is your problem.
What causes a Glow-worm F29 fault?
The flame has to stay lit and steady the whole time the boiler is firing. Anything that interrupts the gas, the air or the spark can put it out. Here are the causes I’d look at, starting with the ones you can check yourself.
| Cause | Tell-tale sign | Usual fix | Who fixes it |
|---|---|---|---|
| Short gas supply interruption | Hob or gas fire also acting up, or prepayment meter at zero | Top up credit or contact your supplier, then reset once | You, or your gas supplier |
| Frozen condensate pipe | Cold snap, F29 appears mid-run, the outside pipe looks iced | Thaw the pipe, then reset once | You, or an engineer if it keeps freezing |
| Flue gas recirculation | Code returns after a few minutes of running | Engineer checks the flue and air supply | Gas Safe engineer |
| Incorrect earthing | Random flame loss with no pattern | Engineer tests and corrects the electrical earth | Gas Safe engineer |
| Ignition spark fault | Clicking at start-up but a weak or failing flame | Engineer checks the ignition transformer and related parts | Gas Safe engineer |
| Gas valve or circuit board | Repeated F29 even after the checks above | Engineer tests and replaces the part if needed | Gas Safe engineer |
Glow-worm lists the gas interruption, flue gas recirculation, earthing and ignition transformer causes for its Energy range. The condensate, electrode and valve causes are ones we often see on boilers like this, but they vary by model.
How do you fix a Glow-worm F29?
You can try a few safe checks. Do them in this order and stop as soon as one of them solves it.
- Check that your hob or gas fire works. If they don’t, the problem is the gas supply, not the boiler.
- If you’re on a prepayment meter, look at the credit and top it up if it’s low.
- In freezing weather, look at the plastic condensate pipe that runs outside from the boiler. If it’s frozen, pour warm (never boiling) water along it.
- Reset the boiler once, following the reset steps in your manual.
If F29 comes back, stop there. Please don’t keep resetting it. Everything else on the list is engineer work, and you should never open the casing or touch any gas parts yourself.
If anything here doesn’t match your boiler, follow your manual instead, and when in doubt, play it safe and call a Gas Safe registered engineer.
Is a Glow-worm F29 fault dangerous?
The code itself isn’t an emergency, because the boiler is switching itself off rather than carrying on with an unstable flame. If you smell gas, though, leave the property, don’t touch any switches and call the National Gas Emergency Service on 0800 111 999. Otherwise, leave the boiler off and book an engineer if the checks don’t clear it.
Should I repair or replace my Glow-worm boiler?
A single F29 on a boiler that has otherwise run well is usually worth repairing. A boiler that keeps losing its flame is a different story. If yours is over 8 years old and out of warranty, get a price for a replacement before you agree to a big repair. A new boiler from our Edinburgh team may work out better value than a run of call-outs.
How can I stop F29 coming back?
Most of the prevention is about the condensate pipe and a healthy flame. Ask for the outside run of pipe to be insulated, or rerouted if it’s long and exposed, because a Scottish winter will find any weak spot. An annual boiler service lets an engineer check the ignition parts, the flue and the earthing before they cause a breakdown.
Glow-worm boiler repairs across Edinburgh and Scotland
The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland. Our engineers are Gas Safe registered and we’re Which? Trusted Traders. We cover every postcode from EH1 to EH55, plus Dalkeith, Musselburgh, Penicuik, Livingston and Dunfermline. If your Glow-worm is showing F29, you can book a Glow-worm repair online, or see the other codes in our Glow-worm fault code hub.
Frequently asked questions about the Glow-worm F29 fault
What’s the difference between F28 and F29?
F28 means the boiler failed to light at start-up, while F29 means it lit and then lost the flame mid-run. Our Glow-worm F28 guide covers the failed start.
Why does F29 only happen in cold weather?
A frozen condensate pipe is one common reason. When the pipe ices up, the waste water can’t drain away, and that can stop the boiler running properly. If it only appears on frosty mornings, that’s a strong clue, so mention it to your engineer.
Is it worth repairing an older Glow-worm that keeps showing F29?
It depends on the cause. A frozen pipe or an empty meter costs little to put right, whereas a failing gas valve or circuit board on an old boiler is harder to justify. Ask for a fixed quote and compare it with a replacement.
Could F29 be linked to a low-pressure fault?
Not directly, as low pressure has its own code. Our Glow-worm F22 guide explains that one.