Glow-worm F5 Fault Code: Causes and How to Fix It

Quick answer: Glow-worm F5 is an overheat fault. The boiler thinks it’s getting too hot and has shut down to protect itself. Poor water flow is a common reason for overheating on any boiler, so make sure your radiator valves are open, then reset once following your manual.

Glow-worm boilers have been fitted in Scottish homes for decades, and plenty of the older ones are still going strong. Seeing a code on one doesn’t mean the boiler is finished, though I’ll be straight with you about what we can and can’t say from the outside.

What does F5 mean on a Glow-worm boiler?

F5 stands for overheat fault. That’s the whole of Glow-worm’s published meaning, and it’s worded the same way across its older model pages. It doesn’t say why the boiler overheated, so the cause has to be found on site.

The code applies to the older Glow-worm boilers, which means the Flexicom range (cx, sx, hx and hxi) and the CI and CI Plus. If you have a newer Glow-worm, such as the Energy range, an overheat is shown as F20 instead, so F5 on a newer boiler would be worth double-checking against your manual.

What causes a Glow-worm F5 fault?

Glow-worm doesn’t list F5-specific causes, so I won’t pretend otherwise. What I can give you is the usual list of reasons that boilers overheat in general. They’re hedged because they aren’t confirmed for this exact code.

Possible causeTell-tale signUsual fixWho fixes it
Poor water flow in the systemRadiators cold or only partly warmOpen valves, bleed radiators, then reset onceYou, then an engineer if it persists
Low water pressurePressure gauge reading below the range in your manualEngineer checks for the reason for the pressure lossGas Safe engineer
Pump not circulating properlyBoiler gets hot but the pipes stay coolEngineer tests the pumpGas Safe engineer
Blockage or sludge in the systemCold patches at the bottom of radiatorsEngineer advises on a system cleanGas Safe engineer
Faulty thermostat or sensorCode appears even when radiators are hot and flow is fineEngineer tests and replaces the partGas Safe engineer

Only an engineer can say which of these it is on your boiler. When you ring, tell us your exact model name and what the radiators were doing when the code appeared. It saves time on the visit and helps us bring the right parts.

Can I reset a Glow-worm F5?

You can try once, but check your manual first because reset steps differ between the older models. Here’s what’s safe.

  1. Let the boiler cool down for a while. Don’t try to restart it while it’s still hot.
  2. Check that your radiator valves are open and that the pressure gauge is in the range your manual gives.
  3. Reset it once, using the steps in your user manual.

If F5 returns, leave it off and call an engineer. Please don’t reset it again and again, and don’t open the casing or touch the pump, wiring or any sensors.

Not certain what your manual allows? Check it before pressing anything, and if in doubt, ring a Gas Safe registered engineer rather than guessing.

Is a Glow-worm F5 fault dangerous?

The code is a safety response, so the boiler stopping is doing its job. A boiler that really is overheating shouldn’t be left running, though. If you smell gas, leave the building and call 0800 111 999. If you hear banging or see steam or leaks, switch the boiler off and call us.

Should I repair or replace my Glow-worm boiler?

This code mostly turns up on older boilers, so the age question matters more than usual. If yours is over 8 years old and out of warranty, ask for a replacement price before agreeing to a big repair. You can look at a new boiler from our Edinburgh team alongside the repair quote.

Does a service prevent a Glow-worm overheat fault?

A service can’t promise it, but it removes many of the usual triggers. An engineer will check the pressure, the pump and how well the system is flowing. Book a boiler service each year, ideally before the cold weather arrives.

Glow-worm boiler repairs across Edinburgh and Scotland

The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland. We’re Gas Safe registered and Which? Trusted Traders, and we cover EH1 to EH55 as well as Peebles, Galashiels, Kelso, Hawick and Dunbar. To get your older Glow-worm looked at, book a Glow-worm repair. You can also browse the Glow-worm boiler error codes.

Frequently asked questions about the Glow-worm F5 fault

What’s the difference between F5 and F20?

Both are overheat faults, but F5 belongs to the older Glow-worm models and F20 to the newer ones. If your boiler shows F5, you’re most likely on a Flexicom or CI.

Can I reset a Glow-worm F5 myself?

Once, yes, following your manual. If it comes back, you need an engineer.

Is it worth repairing an older Flexicom that shows F5?

It depends on the cause and the age. A simple circulation problem is cheap to fix, but a part failure on a boiler past its best may not be. Ask for a fixed quote and compare it with replacing.

Is F5 the same as the ignition faults?

No. Ignition faults are a different problem, covered in our Glow-worm F1 guide.