Quick answer: Glow-worm F9 is linked to the water pressure sensor on older Glow-worm boilers, and depending on your model it can also point to a blocked flow filter or the pump. Look at the pressure gauge, note what it says, and reset once if your manual allows it. After that, this is a job for a Gas Safe engineer.
It’s an odd one, because Glow-worm’s own wording changes from one older model to the next. We see a lot of these boilers across Scotland, and I’d rather give you a short honest answer than guess.
What does F9 mean on a Glow-worm boiler?
F9 appears on the older Glow-worm range, which covers the Flexicom (cx, sx, hx and hxi), the CI and the CI Plus. The meaning isn’t identical across them, so here is how Glow-worm describes it model by model.
On the Flexicom cx, Glow-worm lists a water pressure sensor fault, a blocked flow filter or a pump fault. On the Flexicom sx and hx, it lists a low water pressure sensor. The Flexicom hxi entry is for earlier models only, and Glow-worm tells you to contact its technical team. On the CI and CI Plus, the listing is a water pressure sensor fault. So the same code can point at slightly different parts, depending on the label on your boiler.
Newer Glow-worm boilers don’t list F9 for this. Their pressure and flow codes include F22, F73, F74 and F75.
What causes a Glow-worm F9 fault?
Glow-worm’s code lists don’t give causes for F9, so I can only go as far as its wording allows. The pressure sensor, the flow filter and the pump are the parts it names. Which one it is depends on your model, and only an engineer can tell by testing.
| Possible cause | Tell-tale sign | Usual fix | Who fixes it |
|---|---|---|---|
| Water pressure sensor fault | Gauge reads normal but the code shows | Engineer tests the sensor and replaces it if needed | Gas Safe engineer |
| Low pressure reading | Gauge sits below the range in your manual | Engineer finds why pressure dropped before topping up | Gas Safe engineer |
| Blocked flow filter (cx model) | Radiators slow to warm | Engineer cleans or replaces the filter | Gas Safe engineer |
| Pump fault (cx model) | Boiler runs but water doesn’t circulate | Engineer tests the pump | Gas Safe engineer |
Please don’t treat this as the same job as a low-pressure fault on a newer boiler. Topping up the pressure may not help, and could hide the real problem.
How do you fix a Glow-worm F9?
There isn’t much you can safely do, and that’s deliberate. Start with the gauge, which is on the front panel of most boilers, and write down the reading. It helps the engineer.
- Check the gauge and note the number.
- Look in your manual to see whether a reset is allowed for F9.
- If it is, reset the boiler once.
If the code returns, stop. Don’t repeat the reset, open the casing, or touch the sensor, pump or filter. On an hxi, Glow-worm points you to its technical team, so tell the engineer that when you ring.
If the manual doesn’t match what you’re seeing on the display, don’t improvise. Call a Gas Safe registered engineer to be on the safe side.
Is a Glow-worm F9 fault dangerous?
Not by itself. It’s a fault code that stops the boiler running, rather than a sign of a gas leak. If you ever smell gas, leave the property and call 0800 111 999. Otherwise, switch the boiler off and arrange a visit so the water side can be checked properly.
Should I repair or replace my Glow-worm boiler?
F9 is listed for older models, so age is a real factor. If yours is over 8 years old and out of warranty, get a replacement price before agreeing to a big repair, particularly if parts are hard to find. You can compare the repair with a new boiler from our Edinburgh team.
Does a service prevent a Glow-worm F9?
Regular servicing helps because the engineer checks the pressure, the filter and the pump as part of the visit. It can’t rule out a sensor failing with age. A yearly boiler service is still the best way to catch problems early.
Glow-worm boiler repairs across Edinburgh and Scotland
Our Gas Safe engineers repair, service and replace boilers across Edinburgh and Scotland, and we’re proud to be Which? Trusted Traders. We cover EH1 to EH55 and nearby areas including Paisley, East Kilbride, Perth, Musselburgh and Dunfermline. To get an older Glow-worm checked, book a Glow-worm repair. There’s more in the Glow-worm fault code hub.
Frequently asked questions about the Glow-worm F9 fault
Is F9 the same as F22?
No. F22 is Glow-worm’s low-pressure code and the one you’ll mostly see on newer boilers, while F9 is listed for the older ones. Our Glow-worm F22 guide covers the newer fault.
Should I top up the pressure when F9 shows?
Please don’t, unless your manual says so for your model. The meaning of F9 isn’t always low pressure, and the sensor itself may be at fault.
Which Glow-worm boilers show F9?
The older Flexicom, CI and CI Plus models, according to Glow-worm’s code lists. Newer boilers use different pressure codes, such as F75.
Can I reset an F9 myself?
Once, if your manual allows it. If the code comes back, you need an engineer.