Trustpilot and STV

How to Bleed a Radiator: Step-by-Step Guide

Quick answer: Turn the heating off and let the radiators cool. Hold a cloth under the bleed valve, open it a quarter to half a turn with a radiator key until the hiss stops and water appears, then close it. Check your boiler pressure afterwards, as bleeding often lowers it. If you would rather not do it yourself, a Gas Safe registered engineer can bleed the radiators for you.

It takes about ten minutes and costs nothing. I know a radiator that stays cold while the rest of the house warms up is annoying, especially on a cold Edinburgh morning, but trapped air is one of the easiest heating problems to sort yourself.

How do I know if a radiator needs bleeding?

A radiator needs bleeding when it feels cold at the top and warm at the bottom. Air rises, so it collects at the top and pushes the hot water out of the way.

Other signs are gurgling or hissing from the radiator, and a radiator that takes a long time to warm up. Often the whole radiator heats up poorly, and the house feels colder than it should.

How do you bleed a radiator?

You need a radiator key (cheap from any DIY shop), a cloth and a small bowl. Have your boiler manual nearby too. Work through the radiators one at a time, starting on the lowest floor and moving upwards.

  1. Switch the heating off and wait until the radiators are completely cool.
  2. Look at your boiler pressure gauge and note the reading before you start.
  3. Find the bleed valve. It sits at the top corner of the radiator, on one end.
  4. Hold the cloth under the valve with the bowl below it, to catch any drips.
  5. Fit the key onto the valve and turn it anticlockwise, a quarter to half a turn only. Never unscrew it fully.
  6. Listen for a hiss. That’s the trapped air escaping.
  7. When the hissing stops and a steady trickle of water appears, turn the key clockwise to close the valve. Don’t overtighten it.
  8. Wipe the valve dry, then move on to the next radiator.
  9. When you’ve finished, check the boiler pressure again and top it up if it’s low (see below).
  10. Turn the heating back on and check that each radiator warms evenly from top to bottom.

Heated towel rails usually work the same way. Check for a bleed valve at the top.

If you’re unsure at any point, check your boiler’s manual, and for safety call a Gas Safe registered engineer.

Does the heating need to be off?

Yes, the heating should be off and the radiators cool. Bleeding a hot radiator risks a spray of very hot water or steam, and it can pull more air into the system.

Give it an hour or so after switching off. Then bleed, then switch back on.

What should boiler pressure be after bleeding?

For most sealed systems, UK heating guides suggest about 1.0 to 1.5 bar when the system is cold. One guide gives 1 to 2 bar, so follow the figure in your own boiler’s manual.

Letting air out lets a little water pressure go with it, so the needle often drops. If it’s below the range in your manual, you can top it up through the filling loop. Only do this when the system is cold. A hot system reads falsely high, and you could end up overfilling.

Many homes have a sealed system with a pressure gauge on the boiler. Some older homes have an open-vented system, with a header tank in the loft and no gauge. These work differently, so ask an engineer before you try to top one up.

For a sealed system, the usual top-up goes like this, but your manual comes first because filling loops vary. With the boiler off and cool, open the first filling loop valve slowly, then the second. Watch the gauge and stop slightly before you reach the target. Close both valves fully, restart the boiler and check the pressure holds. If your loop has a filling key, remove or secure it.

If the pressure won’t hold, or you’re not comfortable doing this, leave it and ring a Gas Safe registered engineer.

Why is my radiator cold at the bottom but hot at the top?

That pattern usually points to sludge or restricted flow, so bleeding won’t fix it. Sludge is rusty debris that settles at the bottom of the radiator and blocks the water.

Our guide to magnetic filters and central heating sludge explains what to look for. This table shows what your radiator is telling you.

What you noticeLikely causeWhat to do
Cold at the top, warm at the bottomTrapped airBleed the radiator using the steps above.
Cold at the bottom, hot at the topSludge or restricted circulationBleeding won’t help. Ask an engineer to check the system.
Cold everywhere on one radiatorA stuck valve pin, poor balance, or a faulty valveCheck the valve is open. If it stays cold, ask an engineer.
Several radiators cold, or the whole system is slowLow pressure, or a pump or diverter faultCheck the gauge against your manual, then call an engineer.
Gurgling or hissingAir in the systemBleed the radiators, then check the pressure.

What if no air comes out, or water spurts out?

If no air comes out, the radiator may not have an air problem at all. Close the valve, then check the other causes in the table above.

If water spurts out and no air hisses first, close the valve straight away and mop up. If the valve won’t close, is seized, or keeps dripping, stop and call an engineer. Forcing it can make the leak worse.

A few mistakes catch people out: bleeding a hot radiator, unscrewing the valve all the way, overtightening it afterwards, forgetting to check the pressure, and expecting bleeding to clear sludge.

How often should I bleed radiators?

Once a year is a good habit, and early autumn works well because the heating is about to come on. Bleed again whenever you spot a cold patch at the top of a radiator.

If you find you’re bleeding the same radiators every few weeks, something else is going on. Air getting into the system often has a cause, such as a small leak, and an engineer can track it down. Our tips on maintaining your boiler cover other checks that help between services.

When should I call an engineer?

Call a Gas Safe registered engineer if any of these happen:

  • The bleed valve is seized or leaking.
  • Water spurts out and no air comes first.
  • Several radiators stay cold after bleeding.
  • Boiler pressure keeps dropping.
  • You need to bleed the same radiator again and again.
  • You’re not sure how to top up the pressure.

Not sure who to hire? Our guide to checking the Gas Safe Register shows how to do it.

Cold radiators that won’t clear? Book a boiler repair with our Gas Safe engineers in Edinburgh and we’ll find the cause.

UK guides suggest an engineer might charge about £80 to £100 to bleed 5 to 10 radiators, or £100 to £150 for 12 to 15.*

*Guide figures are based on typical UK repair prices published online, and they’re only a rough steer. Prices vary with the model, parts availability and the job itself, so please treat them as ballpark figures and ask for a fixed quote.

If your boiler is over 8 years old and out of warranty, and an engineer is quoting for a big repair, it’s worth pricing a replacement before you agree. You can ask about a new boiler from our Edinburgh team, with no pressure to book.

Thinking it might be time for a replacement? Get a new boiler quote from our Edinburgh team and compare it with the repair cost.

Can a service stop radiators needing bleeding so often?

A yearly check helps, because an engineer can spot small leaks, low pressure and early signs of sludge. A regular boiler service is the easiest way to catch these.

Heating help across Edinburgh and Scotland

The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland. Our engineers are Gas Safe registered, and we’re Which? Trusted Traders. We cover EH1 to EH55, including Dalkeith, Musselburgh, Penicuik, Livingston, Bathgate and South Queensferry. If a cold radiator won’t sort itself out, book a heating engineer and we’ll take a look.

Frequently asked questions about bleeding radiators

Should the heating be on or off when bleeding a radiator?

Off, and the radiators should be cool. Bleeding a hot radiator can release hot water or steam, so wait until it’s cold to the touch.

Why is my boiler pressure low after bleeding?

Letting air out also lets out a little water, so the pressure often drops. Top it up through the filling loop when the system is cold, following your manual, and call an engineer if it keeps falling.

How much does it cost to have a radiator bled?

UK guides suggest about £80 to £100 for 5 to 10 radiators and £100 to £150 for 12 to 15. Ask for a fixed quote, as prices vary.

Can I bleed a heated towel rail?

Usually yes, using the same method. Look for a bleed valve at the top, switch the heating off first, and check the manual for the rail if you have one.

For more on keeping your heating in shape, see our guide on maintaining your boiler in summer.

Get Your Free Fixed Price Quote