The Potterton fault codes people see most often are E119 for low water pressure, E133 for ignition failure, E110 for overheating, E125 for a circulation fault and E168 for a general internal fault. Most of these lock the boiler out until the cause is dealt with, so you’ll be without heating and hot water until it’s sorted. That’s never fun, but these codes are very familiar to us and most are quite manageable.
Potterton boilers are made by BDR Thermea, the same group behind Baxi, and the very popular Promax and Titanium ranges share a lot of their engineering. That’s why many Potterton codes match the Baxi ones. We fix, service and replace boilers across every Edinburgh postcode from EH1 to EH55 and surrounding towns including Balerno, Bonnyrigg, Dalkeith, Linlithgow, Musselburgh, Penicuik and South Queensferry, and Potterton faults are a regular part of our week, so you’re in familiar hands. If yours keeps throwing codes and is more than around eight years old and out of warranty, a new boiler will usually serve you better than another repair.
Which Potterton do you have, and does it matter?
It matters, because newer Potterton models show a code on a digital display while older ones signal faults with flashing lights.
Promax and Titanium boilers show an E code on the screen, and that’s what the table below covers. Older Performa and Gold models use LED flash patterns instead, where the number of flashes tells you the fault. If your Potterton has no display, check the manual for your model, because the flash codes aren’t the same as the E codes. The model name is usually printed on the front panel or the data plate.
Potterton boiler fault codes at a glance
| Code | What it usually means | Full guide |
|---|---|---|
| E119 | Low water pressure | Baxi E119 guide |
| E133 | Ignition failure or interrupted gas supply | Baxi E133 guide |
| E110 | Overheating, safety thermostat tripped | Baxi E110 guide |
| E125 | Circulation fault in the heating circuit | Baxi E125 guide |
| E160 | Fan or fan wiring fault | Baxi E160 guide |
| E168 | General internal or circuit board fault | Baxi E168 guide |
| E20 | Central heating temperature sensor fault | Baxi E20 guide |
| E28 | Flue sensor or blocked flue | Covered below |
Because Potterton and Baxi share a platform, the linked Baxi guides apply to your Potterton too. Check your own manual for any model-specific differences.
E119: low water pressure
E119 means the system pressure has dropped too low, and the boiler has shut down to protect itself. It’s the code you can most often clear yourself, so it’s a gentle one to start with.
Look at the gauge on the front. With the system cold it should sit around 1 to 1.5 bar. If it’s low, find the filling loop under the boiler, open the valves slowly until the needle reaches about 1.2 bar, close them firmly and press reset. If it drops again within days you’ve got a leak somewhere, and that needs an engineer. Our Baxi E119 guide walks through it step by step.
E133: ignition failure
E133 means the boiler tried to light and couldn’t, or the gas supply was interrupted partway through. In winter the most common culprit is a frozen condensate pipe.
Check your hob or another gas appliance first. Then look at the condensate pipe outside. If it’s frozen, warm water poured over it (never boiling) usually clears it. Reset once. If E133 returns, the electrodes or gas valve probably need attention. Read the Baxi E133 guide for the full checklist.
E110: overheating
E110 means the safety thermostat has switched the boiler off because the water inside got too hot. Air in the system, poor circulation or a failing pump are the usual reasons.
Switch off, let it cool for half an hour, check the pressure, bleed any radiators that are cold at the top, and reset once. Repeat overheating needs a Gas Safe engineer. See the Baxi E110 guide.
E125: circulation fault
E125 means the boiler can’t confirm that water is moving properly through the heating circuit. A seized pump after the summer is a classic cause, and sludge in older systems is another.
Check the pressure, listen for the pump when the boiler tries to start, and reset once. If it persists, the pump or the system may need work. The Baxi E125 guide has the detail.
E160: fan fault
E160 means the boiler can’t confirm the fan is running at the right speed. It could be a worn fan, loose wiring or a blocked flue.
Clear anything visibly blocking the flue terminal, reset once and call an engineer if it returns. More in our Baxi E160 guide.
E168: general internal fault
E168 means the boiler has detected a problem but can’t say exactly what it is. It often follows a reset, a power cut or an earlier fault.
If you saw a different code before E168 appeared, note it down, because it helps the engineer. Switch the boiler off at the isolator for a minute, switch it back on, and try one reset. If it keeps returning, it’s usually a circuit board or wiring issue and needs a Gas Safe engineer. It’s also the type of fault that tends to repeat on older boilers. Our Baxi E168 guide goes into more detail.
E20 and E28: sensors and flue
E20 points to the central heating temperature sensor, and E28 points to the flue sensor, air pressure switch or a blocked flue or condensate path. In both cases the boiler can’t read what it needs to run safely, so it locks out. A sensor needs replacing by an engineer, and a blocked flue or frozen condensate pipe is worth checking first on a cold day. Our Baxi E20 guide covers the E20 sensor fault in detail.
Older Potterton models with flashing lights
If you have a Performa or Gold, the fault shows as a flash pattern rather than a number. The number of flashes matches a fault in your boiler’s manual, so keep it handy. If you can’t find it, a Gas Safe engineer can read the fault in seconds. These models are well past the point where we’d recommend more than essential repairs, and replacement is usually the better value.
Need help with a Potterton boiler in Edinburgh or Scotland?
The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland. Our Gas Safe engineers are Which? Trusted Traders, and we’re accredited installers you can check for yourself. If your Potterton keeps showing codes, book a Potterton repair or request a free quote for a new boiler. Got a different make? Our guide to boiler error codes for every major brand has you covered, and our Baxi boiler error codes guide goes into more detail on the shared codes.
Frequently asked questions about Potterton fault codes
Are Potterton fault codes the same as Baxi codes?
Mostly, yes. Both brands are made by BDR Thermea and the Promax and Titanium models share a platform with their Baxi equivalents. Your manual is the final word for your exact model.
How often should a Potterton boiler be serviced?
Once a year by a Gas Safe engineer. A boiler service catches worn electrodes, sensors and pump problems before they lock the boiler out.
Is it worth repairing an old Potterton?
If it’s over eight years old, out of warranty and showing repeat faults, replacement often works out better value over a few years once energy savings are counted. We’ll give you both numbers.
What should I do if I smell gas?
Turn the boiler off at the isolator, open windows, avoid electrical switches and call the National Gas Emergency number on 0800 111 999. Don’t reset the boiler or try any repair.
Can I reset my Potterton more than once?
Once is fine, so don’t worry if you’ve already tried it. If the fault returns, repeated resets won’t fix the cause and a Gas Safe engineer needs to look at it.