Vaillant F73 Error Code: Causes and How to Fix It

Quick answer: The Vaillant F73 fault means the boiler’s water pressure sensor isn’t giving a proper reading, usually because the sensor itself is faulty or its plug or wiring has a problem. First check the pressure gauge. If the system really is low, top it up and reset once. If the gauge looks normal and F73 stays, you need a Gas Safe engineer.

Seeing a fault code on a Vaillant is never fun, especially when the heating’s off, but F73 is one of the more straightforward ones to get to the bottom of. Vaillant is a very popular name in Edinburgh homes, and we see this code on ecoTEC and other models regularly. If your boiler is more than around eight years old and out of warranty, repeat sensor faults are a fair reason to compare repair costs with a new boiler from our Edinburgh team.

What does the Vaillant F73 error code mean?

F73 means the water pressure sensor signal is out of range, or the sensor appears to be disconnected or short-circuited.

The sensor tells the boiler how much pressure is in the heating system. If that signal goes missing or looks wrong, the boiler can’t tell whether it’s safe to run, so it stops. The important point is that the code is about the sensor’s signal, which isn’t always the same as the actual pressure.

What causes a Vaillant F73 fault?

The usual causes are a faulty pressure sensor, a loose or disconnected plug, damaged wiring, or, less commonly, a circuit board fault.

  • Faulty sensor: it gives a wrong reading or none at all
  • Loose or unplugged connection: the plug has worked loose, or the wire has come away
  • Damaged wiring: water damage to the cable is a common culprit if there’s been a leak nearby
  • Circuit board: the board can’t read the sensor’s signal, which is the least likely cause
  • Genuinely low pressure: sometimes the system really is low and the sensor is reporting it correctly

How do you fix a Vaillant F73 error?

Look at the pressure gauge first. If the pressure is low, top it up and reset once. If it reads normally and F73 stays, call an engineer.

  1. Check the gauge on the front. With the system cold, it should sit around 1 to 1.5 bar.
  2. If it’s low, use the filling loop to bring it up slowly to about 1.2 bar, then close the valves firmly.
  3. Look underneath the boiler for any signs of water or dripping, and mention it to your engineer if you see any.
  4. Press reset once.
  5. If F73 returns with a normal gauge reading, leave the boiler off and book a Gas Safe engineer.

Sensors, plugs and wiring are engineer jobs, so please don’t open the boiler casing. Leave the fiddly bit to us.

Is Vaillant F73 the same as F22?

No. F22 means the pressure really is low, while F73 means the boiler can’t get a proper reading from the pressure sensor.

They’re easy to mix up, since both involve pressure. If your gauge shows normal pressure but the boiler is still complaining, F73 is the likelier explanation. Our guide to the Vaillant F22 error covers real low pressure, and the Vaillant F75 covers a pump or pressure sensor problem where the boiler doesn’t see the expected pressure change when the pump starts.

Does servicing help prevent F73?

It can, because an engineer checks the connections, the pressure and any signs of leaks during a boiler service. A loose plug or a weeping joint spotted early is a far cheaper fix than a lockout in January.

When should you call an engineer for a Vaillant F73?

Call a Gas Safe engineer if F73 returns after one reset, if the gauge reads normally, or if you’ve noticed any water around the boiler. Replacing a sensor or tracing a wiring problem needs the right tools and a qualified person.

Vaillant boiler repairs across Edinburgh and Scotland

The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland. Our Gas Safe engineers cover every Edinburgh postcode from EH1 to EH55, plus Balerno, Bonnyrigg, Dalkeith, Linlithgow, Musselburgh, Penicuik and South Queensferry. We’re Which? Trusted Traders, and our team has seen plenty of pressure sensor faults. If your Vaillant is showing F73, arrange a repair visit with our team and we’ll get your heating going again.

Frequently asked questions about the Vaillant F73 error

Is a Vaillant F73 fault dangerous?

Try not to worry, the lockout is a protective response, so it’s the safe outcome. If you ever smell gas, turn the boiler off at the isolator, open windows and call 0800 111 999.

How many times should I reset my Vaillant after F73?

Once, so don’t worry if you’ve already tried it. If it returns, repeated resets won’t fix a sensor or wiring problem.

What’s the difference between F73 and F74?

Both relate to the water pressure sensor. F73 usually points to the signal being too low, or the sensor being disconnected or short-circuited, while F74 points to an electrical problem with the sensor or its cable. Either way, an engineer needs to look at it. Our guide to Vaillant boiler error codes lists the rest.

Is it worth repairing an older Vaillant that keeps showing F73?

If it’s over eight years old and out of warranty, sensor and wiring faults tend to arrive in a run. A Gas Safe engineer can give you a clear repair-or-replace comparison, and you can request a free quote at the same visit.