Quick answer: A01 on a Vokera boiler means an ignition failure. The boiler tried to light but couldn’t detect a flame, so it locked out. Check your gas supply, make sure the condensate pipe isn’t frozen and reset once. If A01 comes back, a Gas Safe engineer will need to look at the ignition electrode, gas valve or burner.
The Vokera Easi-Heat and Compact are very popular in Scottish homes, especially flats, rentals and newer builds, so A01 is a code we see quite a bit. It’s one of the most common faults on any boiler, and the cause is often simple. If your heating and hot water have just gone off, hang in there. There’s a good chance you can get things going again yourself in a few minutes.
What does A01 mean on a Vokera boiler?
A01 means the boiler failed to ignite because it didn’t sense a flame. After a set number of attempts, it locks out for safety.
On older Vokera models you may see the same fault shown simply as 01. Lots of people type it as “AO1” with a letter O, and that’s the same code too. Vokera has made a lot of different boilers over the years and display codes can vary a little between them, so your user manual is worth a look if the description doesn’t seem to fit.
What causes a Vokera A01 fault?
The most common causes are a problem with the gas supply, a frozen condensate pipe, a worn ignition electrode, a faulty gas valve or a dirty burner.
| Cause | Can you check it? | Engineer fix |
|---|---|---|
| Gas supply off or meter out of credit | Yes | None needed once gas is restored |
| Gas valve under the boiler closed | Yes, look but don’t force it | Open and check the supply |
| Frozen condensate pipe | Yes | Thaw, then insulate the pipe |
| Worn or dirty ignition electrode | No | Clean, adjust or replace |
| Faulty flame sensor | No | Test and replace |
| Faulty gas valve | No | Test and replace |
| Blocked burner | No | Clean and check combustion |
What can I check before calling an engineer?
Start with the gas and the condensate pipe. Between them, they account for a big share of A01 call-outs, particularly in winter.
- Check your hob or other gas appliances. If they don’t work either, the problem is the gas supply, not the boiler.
- On a prepayment meter, make sure there’s credit and the emergency credit hasn’t run out.
- Check the gas tap on the pipe under the boiler is open. The handle should line up with the pipe.
- In freezing weather, find the plastic condensate pipe running outside. If it’s frozen, pour warm (not boiling) water along it until it thaws.
- Look at the flue outside to make sure nothing is blocking it.
- Reset the boiler once.
If you smell gas at any point, don’t touch any switches. Open the windows and call the National Gas Emergency number on 0800 111 999.
How do I reset a Vokera after an A01?
Press the reset button and the boiler should try to light again. The exact button, and how long you hold it, varies between Vokera models, so check your user guide.
Reset once. If A01 comes back straight away, or after a few hours, stop resetting. Each attempt sends gas to the burner, and if it isn’t lighting, there’s a fault that needs finding.
Is Vokera A01 dangerous?
The lockout keeps you safe, because the boiler stops trying to light rather than letting unburnt gas build up. It’s a sensible safety feature.
As long as you can’t smell gas and your carbon monoxide alarm is quiet, there’s no immediate danger. You’re just without heating until it’s fixed.
Should I repair or replace my Vokera?
If it’s the ignition electrode, that’s one of the cheaper boiler repairs and well worth doing. A failed gas valve on an older boiler is a different story.
For a Vokera that’s over eight years old and out of warranty, a gas valve can cost enough that a new boiler from our Edinburgh team makes more sense. A modern A-rated boiler should be cheaper to run, and you’ll be back under warranty.
How do I stop A01 coming back?
An annual boiler service keeps the electrode, burner and flame sensor clean and properly set, which prevents a lot of ignition faults.
If frozen condensate pipes keep catching you out, ask us about insulating or rerouting the pipe. It’s a small job that saves a lot of hassle in a Scottish winter.
Vokera boiler repairs across Edinburgh and Scotland
The Edinburgh Boiler Company repairs, services and replaces boilers across Edinburgh and Scotland. Our Gas Safe engineers cover every Edinburgh postcode from EH1 to EH55, along with Livingston, Broxburn, Bathgate, Dalkeith and Musselburgh. We’re Which? Trusted Traders, and ignition faults like A01 are bread and butter for us. If your Vokera won’t light, book a Vokera repair and we’ll get you warm again. Our Vokera fault code guide covers the other codes.
Frequently asked questions about the Vokera A01 fault
Why does my Vokera keep showing A01?
If A01 keeps returning after the gas and condensate pipe have been checked, there’s likely a worn ignition electrode, flame sensor or gas valve. An engineer will need to test them.
Can a frozen pipe cause A01?
Yes. A frozen condensate pipe can stop the boiler lighting properly, and it’s one of the most common causes in cold weather. Thawing it with warm water usually does the trick.
Is A01 the same as 01 on a Vokera?
Yes, they describe the same ignition failure. Older displays just show the number without the letter.
Do other boilers have the same fault?
Every brand has its own ignition fault code. On a Vaillant it’s F28, and on an Ideal it’s L2. The causes and checks are very similar.